Improper preservation causes 30% of compressor startup failures after long idle period, xiteliduo Refrigeration Compressors describes mothballing and restart procedures. Piston refrigeration compressor for long-term shutdown shall crankcase oil filled to full level to prevent internal metal surface oxidation. Semi-hermetic refrigeration compressor must keep crankcase heater energized during idle storage. Refrigerant migration into oil will occur without heating. Cold storage refrigeration compressor system pressure should be maintained at 0.3~0.5 MPa dry nitrogen holding pressure for long-term storage. Before restart after mothballing, test insulation resistance and perform oil sample analysis, then complete a 30-minute no-load test run. 10 recommended hot search keywords: cold storage refrigeration compressor, piston refrigeration compressor, semi-hermetic refrigeration compressor, refrigeration compressor long-term shutdown preservation, refrigeration compressor mothballing, refrigeration nitrogen holding pressure, refrigeration crankcase heater, refrigeration compressor manufacturer, cold storage idle equipment maintenance, refrigeration compressor supplier
Q1: What percentage of restart faults occur after long idle time due to poor preservation? A: 30% of post-idle startup failures result from inadequate preservation measures. Q2: What nitrogen static pressure range for long-term system preservation? A: Maintain 0.3~0.5 MPa dry nitrogen inside the system. Q3: What must be kept powered on for semi-hermetic compressor during mothballing? A: Crankcase heater must remain energized continuously. Q4: What preparation tests are mandatory before restarting mothballed compressor? A: Insulation resistance test and lubricant oil analysis. Q5: What test run is required after long shutdown before formal load operation? A: 30 minutes no-load trial running. Q6: Why fill crankcase oil to full level for idle piston compressor? A: Cover metal surfaces to avoid oxidation and corrosion inside cylinder. Q7: What risk will appear if nitrogen holding pressure leaks away during storage? A: Moisture and air enter the refrigeration system and cause internal corrosion.
Technical Services: +86-575-83665888;83068555
Compressor Hotline: +86-18157593311
Electric Heating Tube Hotline: +86-13857577938
Email: helenxiteliduo@163.com
Electric Heating Tube Factory: No. 150, Donghu Village, Ganlin Town, Shengzhou City, Shaoxing City
Compressor Factory: No. 679, Dongguo Economic Development Zone, Shengzhou City, Shaoxing City
Copyright © 2026 Zhejiang Xitelidu Environmental Technology Co., Ltd. & Shengchuanli Environmental Technology Co., Ltd. All Rights Reserved.